Tri-High Triga series hollow fiber UF membrane is inside-out filtration style, membrane modules are put into pressure vessels in series and connected by adapter, the membrane pore size is less than 0.010μm. Triga UF membrane has unique water flow design and special inner structure, it has obvious advantages while applying in the power plant, steel plant, sea water desalination, etc. and there are many successful references both in domestic and abroad.
Application:
Advanced Treatment and Reuse Systems for Industrial Wastewater and Municipal Sewage
Reverse Osmosis (RO) or Seawater Desalination Pretreatment Systems
Pure Water Production, Drinking Water Purification
Membrane Parameters:

Membrane parameters
|
Module Model
|
Membrane area (m2 ) |
A, Module Length (mm) |
B, Module outer side size (mm) |
C, Collection pipe diameter (mm) |
|
TRIGA-8P-XL150 |
40 |
1527.5 |
200 |
42.7 |
Technical Parameters:
Technical Parameters
|
Membrane Material |
PS |
|
Membrane Pore Size |
0.8mm |
|
Molecular Weight Cut-off, Daltons |
50000/100000 |
|
Operating Temperature |
1-40℃ |
|
Flux |
30-120L/m2.h |
|
Operating Pressure |
≤0.4Mpa |
|
pH Range |
2-11 |
|
Maximum Transmembrane Pressure Difference |
2.0bar |
|
Maximum Backwash Pressure |
2.5bar |
|
Influent Turbidity |
<10NTU |
|
Maximum Tolerable Residual Chlorine Concentration |
500 |
|
Membrane Housing Material |
UPVC |